Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (16)
  • Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
  • Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
  • Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
  • Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
  • Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
  • Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Contact us
  • Company Profile
  • After Sales Service
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
BK-AA320N
Certification
CE
Product Name
Atomic Absorption Spectrophotometer
Model
Bk-AA320n
Wavelength
190~900nm
Wavelength Accuracy
Less Than 0.5nm
Wavelength Repeatability
≤ 0.3nm (Single Direction)
Spectral Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Grating
1800 Lines/mm
Resolution
<40%
Base Line Stability
±0.004ABS/30min
Characteristic Concentration
≤ 0.04μg/Ml/1% (Cu)
Background Calibration
More Than 30 Times
Power Supply
220V, 50/60Hz
Packing Size(mm)
1250*795*765 (Main Instrument) 545*445*1385 ( Acce
Gross Weight(Kg)
138kg (Main Instrument) 56kg ( Accessories )
Transport Package
Carton Box
Specification
1250*795*765mm(
Trademark
BIOBASE
Origin
China
Production Capacity
100

Product Description

Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory

Product Description

Introduction:

Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
 
Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
 

Features:

1. Build-in computer data processing and LCD display.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
3. Quickly: The cathode lamp does not need to be pre-heated for long time and sample can be analyzed immediately.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
6. High energy optical path.
7. Long-life and anti-corrosive atomization system.
8. Multi-functional analysis mode: a. flame absorption b. flame emission c. graphite furnace atomic absorption d. hydride generation.
9. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.

Product Parameters

Model
BK-AA320N
Wavelength Range
190~900nm
Wavelength Accuracy
≤±0.5nm
Wavelength Repeatability
≤ 0.3nm (single direction)
Spectral Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Grating
1800 lines/mm
Resolution
<40%
Base Line Stability
±0.004Abs/30min
Characteristic Concentration
≤ 0.04μg/ml/1% (Cu)
Detection Limit
≤0.008μg/ml (Cu)
Background Calibration
>30 times
Power Supply
220V, 50/60Hz
Packing Size(mm)
1250*795*765 (Main instrument)
545*445*1385 ( Accessories )
Gross Weight(kg)
138Kg (Main instrument)
56Kg ( Accessories )
Standard Accessories
RS232 serial port
Oil-free air compressor
Glass Atomizer
Cu Hollow cathode lamp
Atomizer unit, Burner unit ,Dust cover
Water-separating gas filter
Titanium burner---10cm
Optional Accessories
Model GA3202 HGA graphite furnace system
Hydride generator
Graphite tubes
Recirculating cooling water system
Hollow cathode lamp(Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K, AU, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)

Contact us

Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory

Company Profile

Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory

Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory

Biobase 190~900nm Atomic Absorption Spectrophotometer for LaboratoryBiobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory

After Sales Service

Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory
 

Packaging & Shipping

Biobase 190~900nm Atomic Absorption Spectrophotometer for Laboratory

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More