  • High Accuracy: Accuracy error is less than 0.5% (D50 value of standard sample) for reliable particle size measurement.
  • Excellent Repeatability: Repeatability error is less than 0.5% (D50 value of standard sample) for consistent results.
  • Wet Method Testing: Designed for wet dispersion analysis with integrated circulation and stirring system.
  • Advanced Optical Design: Converging Fourier transform test technology maximizes short focal length range and improves resolution.
  • High-density detector: 76 channels for strong small particle detection capability.
  • Anti-dry ultrasonic: Prevents damage when operating without water.

Product Images of Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab

Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab pictures & photos
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab pictures & photos
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab pictures & photos
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab pictures & photos
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab pictures & photos
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab pictures & photos
Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
  • Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
  • Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
    Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
  • Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
    Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
  • Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
    Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
  • Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
    Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
  • Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
    Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
  • Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
    Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab

Find Similar Products

Product Description



Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for LabBiobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab
Product Description

Model

BPSA-2020L

BPSA-5100H

BPSA-5200H

BPSA-6100C

BPSA-6100D

Test Method

Dry method

Wet method

Wet method

Wet method

Dry and wet method

Test Range

0.1~800μm

0.1~800μm

0.1~1000μm

0.1~2000μm

Dry method: 0.1~1500μm; wet method: 0.01~1500μm

Number of Detector Channels

87

76

86

96

Dry method: 96; wet method: 127

Accuracy Error

<1% (D50 value of standard sample)

<0.5% (D50 value of standard sample)

<0.5% (D50 value of standard sample)

<0.5% (D50 value of standard sample)

<0.5% (D50 value of standard sample)

Repeatability Error

<1% (D50 value of standard sample)

<0.5% (D50 value of standard sample)

<0.5% (D50 value of standard sample)

<0.5% (D50 value of standard sample)

<0.5% (D50 value of standard sample)

Dispersion

High-pressure air dispersion; mechanical stepless speed-regulating vibration feeding; oil-free silent air compressor with dust filtration function, continuously adjustable from 0.1-0.8MPa; can filter moisture from the air.

Ultrasonic frequency: f=40KHz, power: p=80W, time: adjustable; equipped with ultrasonic anti-dry-burning feature.

Integrated circulation and stirring design, speed: 100~3950rpm adjustable.

Rated circulation flow rate: 0~10L/min adjustable; Rated power: 25W.

Dry method: High-pressure air dispersion; mechanical stepless speed-regulating vibration feeding; oil-free silent air compressor with dust filtration function, continuously adjustable from 0.1-0.8MPa; can filter moisture from the air.

Wet method: Ultrasonic frequency: f=40KHz, power: p=80W, time: adjustable; equipped with ultrasonic anti-dry-burning feature.

Integrated circulation and stirring design, speed: 100~3950rpm adjustable.

Rated circulation flow rate: 0~10L/min adjustable; Rated power: 25W.

Power Supply

Standard: AC220V, 50/60Hz; optional: AC110V, 50/60Hz

Product Size (W*D*H)

700*495*300mm

980*410*450mm

800*280*335mm

800*280*335mm

1040*505*335mm

Net Weight

35kg

30kg

38kg

38kg

50kg

Packing Size(W*D*H)

840*390*500mm

580*380*440mm

430*430*590mm

450*450*720mm

350*350*400mm

940*420*520mm

1200*500*500mm

1200mm*380mm*520mm

700mm*400mm*530mm

430mm*430mm*590mm

350mm*350mm*400mm

450mm*450mm*795mm

Gross Weight

41kg

21kg

10kg

30kg

12kg

45kg

55kg

52kg

33kg

10kg

12kg

38kg

 

 
Company Strength

Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for LabBiobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab

Trade show participation

Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab

 

Factory

Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for LabBiobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for LabBiobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab

Packaging & Shipping

Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for LabBiobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab

After Sales Service

Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for LabBiobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab

 
Contact us

Biobase One-Button Operation Automatic Laser Particle Size Analyzer Bpsa-5100h for Lab

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI2451761". Items marked "verified" are certified.

Watch Video
Watch Video
Biobase Biosun Co., Ltd.
Biobase Biosun Co., Ltd.
Biobase Biosun Co., Ltd.
Biobase Biosun Co., Ltd.
Biobase Biosun Co., Ltd.
Biobase Biosun Co., Ltd.
Biobase Biosun Co., Ltd.
Biobase Biosun Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Biobase Group, Licheng District, Jinan, Shandong, China
verified Plant Area
60 square meters
verified Number of Employees
6
verified Registered Capital
3,000,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Qingdao Port
verified Minimum Order Quantity
1 Pc
verified Supply Chain Partners
20

Our Production Capability & Technical Expertise

verified Main Products
Laboratory instruments, Medical equipment
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2023-01-11
verified Export Year
2 Years
verified Main Markets
North America, Southeast Asia/ Mideast, Africa
verified Repeat Buyers Choice
50%~80%
verified Annual Export Revenue
4,837,001.31 RMB
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What is the measurement principle of BPSA-5100H?
It measures particle size according to the principle of light scattering (laser diffraction).
What testing method does BPSA-5100H use?
BPSA-5100H uses the wet method for particle size analysis.
What is the accuracy of BPSA-5100H?
The accuracy error is less than 0.5% (D50 value of standard sample).
What is the repeatability of BPSA-5100H?
The repeatability error is less than 0.5% (D50 value of standard sample).
Does BPSA-5100H have ultrasonic dispersion?
Yes. Ultrasonic frequency is 40KHz with 80W adjustable power. It also features anti-dry burning protection.